HI 2151/30WC MANUAL

7-16

SUB-CMD

Meaning

REM

Level status of the Remote Input connector (J2)
pins.

Bit

Remote Function Bit

Remote Function

01

Rate of change

10

Net

02

Totalizer

20

Lbs/Kgs

04

Display Hold

40

Tare

08

Option Hold

80

Print

5. Q

The query command obtains a block of information as
follows:

SUB-CMD

Meaning

A.

Gross weight (6 bytes plus label)

B.

Net weight (6 bytes plus label)

C.

Peak gross value reached (6 bytes plus label)

D.

Internal counts (6 bytes)

E.

Total net accumulation (6 bytes plus label)

F.

Rate of change value (6 bytes plus label)

G.

Not Used (6 bytes set to 000000)

H.

Not Used (6 bytes set to 000000)

I.

LED status (4 bytes)

J.

Relay status (2 bytes)

Command

Meaning

F

Format the output data. Used to
configure data to be sent on a
TRANSMIT or PRINT request.
The SUB-CMD letters can be
issued in any combination or
order and are as follows:

SUB-CMD

Meaning

G

Gross

N

Net

T

Tare

R

ROC

S

Set point, Deadband, Preact

NOTE:

The last (6th) position is one of the following (must be accompanied by at least one of
the above SUB-CMDs):

-

Continuous printing.

P

Button on front panel "triggers" output.

NOTE:

The default FORMAT is GNTRSP.