7-18

For example, to set point one to 1000 Lbs gross on instrument number
10, the outgoing command would be as follows:

NOTE:

The example uses decimal and mnemonic abbreviation format for clarity, however,
the actual data would be in ASCII format.

Command

Meaning

C

Allows you to change modes between Net/Gross,
lb/kg, or Hold/Unhold Display.

SUB-CMD

Meaning

M

Toggles between Net and Gross weight mode.

U

Unit (toggles between Lbs. and Kg.)

H

Toggles between display hold and unhold.

Command

Meaning

A

Used to auto tare or auto zero the instrument.

SUB-CMD

Meaning

T

Auto tare the instrument. (Scale must not be in
motion.)

Z

Auto zero the instrument.(Scale must not be in
motion and mode must be set to Gross)

P

Print command. Functionally the same as the print
button on the key board.

The data setup through the format command will be
sent to the port configured as a printer.

Command

Meaning

P1 or P2

Print to either ports 1 or 2.

An optional "subcommand" of up to 37 ASCII characters may be
entered and will be printed before the formatted data.

SUB-CMD

Meaning

37 ASCII characters maximum.

H

The ASCII characters supplied in the subcommand
(maximum of 20 characters) will be printed as a
heading and saved for each subsequent X - transmit

START

CHAR

INSTRUMENT

ADDRESS

CMD

SUB

CMD

CMD

7 BYTE

DATA

D-7 . . . D-1

MODE

CR

2 BYTE CHECKSUM

EOT

CHK-1

CHK-2

>

10

S

S

1

1000

G

CR

CHK-1

CHK-2

EOT