Step 4.

Press the Enter button. RS-232 appears. RS-232 is the default
setting from the factory.

Step 5.

To select RS-232, press on the Enter button.

Step 6.

To select another port use the up or down arrows to select
another serial option.

Step 7.

Select either RS-422, or RS-485.

Step 8.

Press the Enter button to set the port setting. If the jumpers are
in the correct position the unit accepts the setting. Press exit to
return to the main menu.

Step 9.

If the jumpers are not in the correct position or there are no
jumpers installed, a jumper error (JMPERR) will appear.

Go through the configuration again to select the correct
jumper position or install a jumper in the correct position.
(See Chapter 4 for instructions.)

Repeat steps 2 - 8.

Press the Enter button to set the port setting.

Press the Exit button to return to the main menu.

Bar Graph Setup
Procedures

About Bar Graph
Setup

The user can set the bar graph parameters by entering the lowest weight
(value) and the highest weight (value) of the scale or any portion of the
scale. When the user selects the Bar Graph function, the bar graph dis-
plays the current reading as a percentage of the selected scale range
(e.g. 60 pounds on a scale from 0-100 lbs will read 60%). The bar graph
can be setup to indicate Net Weight, Gross Weight and the options
Totalizer, Rate-of-Change and Peak. Keep in mind that the bar graph
can be totally independent of the displayed values.

Step 1.

Press the Options button. The Options (OPTINS) sub-menu
appears.

Step 2.

Press the up arrow until BAR GR appears.

Step 3.

Press the Enter button. BAR LO appears. This is the sub-
menu to select the lowest weight in the selected scale range.

Step 4.

Press the Enter button.

Step 5.

If a value is present, press the test/clear button to clear the
value. Use the numeric key pad to enter the new low value.

Step 6.

Press Enter to select the new value. A GOOD will appear
briefly if the setting is correct.

Step 7.

BAR HI appears This is the sub-menu to select the highest
weight in the selected scale range.

Step 8.

Press the Enter button.