Chapter 4 - Configuration

4-9

FIG. 4-11 PEAK HOLD MODE DIP SWITCH LOCATION

Configuring Multidrop S3-1

When the switch is ON it enables communication to more than one
controller on the same line. To use the Multidrop function the Hardy
Link software option must be installed. Multidrop is only available
when using the RS-422/485 serial port setting.

Configuring Serial S3-3

1. Serial Port Lockout. When the switch is ON, the following com-

mands cannot be executed over the serial interface:

Format
Set Setpoints

2. When the Serial switch is OFF it enables these commands. OFF is

the default position.

Configuring Option S3-4

1. When the switch is ON, there is no access to the Option Menu.

2. When the switch is OFF, the full Option menu is available.

Configuring Set Point S3-5

1. When the switch is ON, there is no access to the Set Point Menu.

2. When the switch is OFF the Set Point Menu is available.

Set Point S3-6

Not Used.

Configuring Lock S3-7

1. When the switch is ON, the Tare, Mode, Zero, and lb/kg keys are

locked out or not available.