Chapter 3 - Installation

3-21

FIG. 3-17 RIO CARD/PIN LAYOUT

Connector Wiring:

1

Blue (1/2 of twisted pair)

2

Shield (outer braided cable shield)

3

Clear (1/2 of twisted pair)

4

No Connection

5

No Connection

6

Wire to instrument chassis ground

Profibus Interface
Option -B12

Refer to Hardy Instruments Profibus Interface Option for the HI 2151/
30WC Installation and Operation Manual for installation instructions.

The Profibus option card can be mounted in either option slot one or
two. However, there is a limit of one Profibus card per instrument.

Connector Cable Wiring:

Top Row Right to Left

J1-1

Ground (outer braided shield)

J1-2

No Connection

J1-3

Transmit (1/2 of twisted pair)

J1-4

No Connection

J1-5

No Connection

Bottom Row Right to Left

J1-6

No Connection

J1-7

No Connection

J1-8

Receive (1/2 of twisted pair)

J1-9

No Connection