Sneak operation – PRG Vx76 User Manual 3.6 User Manual

Page 114

Advertising
background image

98

VX76 SOFTWARE USER MANUAL

Sneak Operation

Sneak values are entered using the [Sneak] button and either the Timing Filter

or

Function Filter screen. After the

sneak operation has been defined, pressing the Timing Filter’s

ENTER



button or the Function Filter’s

TO CUE

button will cause all selected luminaires to move into the new position as defined by the values. The values are
entered numerically at the keypad.

Perform a sneak action using current timing information:

Step

1. Select channels as required.

Step

2. Bring up either Timing Filter

or

Function Filter screen.

Step

3. Select parameter to be changed.

Step

4. At keypad, press [Sneak] and enter required value, press [Enter].

Step

5. At filter, select next parameter and enter its value using keypad.

Step

6. When finished, press Timing Filter’s

ENTER



button

or

Function Filter’s

TO CUE

button. Selected

luminaires will move into the new position as defined by the values.

Sneak to a preset (same for color and beam):

Step

1. Select channels as required.

Step

2. Bring up either Timing Filter

or

Function Filter screen.

Step

3. Select parameter to be changed.

Step

4. At keypad, press [Sneak] [Preset] [x] [Enter] (where x is the discrete preset number)

or

press and hold

[Sneak] while pressing

Preset Palette Button

.

Step

5. Press Timing Filter’s

ENTER



button

or

Function Filter’s

TO CUE

button. Selected luminaires will move

into the new position as defined by the preset data.

To Sneak Cue data:

Step

1. Select channels as required.

Step

2. Bring up either Timing Filter

or

Function Filter screen.

Step

3. Select parameter to be changed.

Step

4. At keypad, press [Sneak] [Cue] [x] [Enter] (where x is discrete cue number).

Step

5. Press Timing Filter’s

ENTER



button

or

Function Filter’s

TO CUE

button. Selected luminaires will move to

the cue selected.

Note: Cue numbers with decimals can be entered into sneak. For example, [Sneak] [Cue] [1] [.] [3] [Enter] will enter
Cue 1.3 into the selected parameter. Even cues without a decimal value will be displayed as a decimal value (1 is
1.00).

Note: Sneak cue data will recall data only for the selected parameters from the given cue, which can be used as a
selective recall tool.

Perform a sneak action using new timing information:

Step

1. Select channels as required.

Step

2. Bring up either Timing Filter

or

Function Filter screen.

Step

3. Select parameter to be changed.

Step

4. At keypad, press [Sneak] and enter required value, press [Enter].

Step

5. To enter time, press [Sneak] [Time] and time value. Press [Enter].

Step

6. Press Timing Filter’s

ENTER



button

or

Function Filter’s

TO CUE

button. Selected luminaires will move to

their new values using their time settings.