Carrier Streamline Scroll 69NT20-531-300 User Manual

Page 13

Advertising
background image

1-1

T-309

SECTION 1

INTRODUCTION

1.1 INTRODUCTION

The Carrier Transicold model 69NT20--531-300 units

are of lightweight aluminum frame construction,

designed to fit in the front of a container and serve as the

container front wall.
They are one piece, self-contained, all electric units

which are fitted with cooling and heating systems to

provide precise temperature control.
The units are supplied with a complete charge of

refrigerant R-134a and compressor lubricating oil and

are ready for operation upon installation. Forklift

pockets are provided for unit installation and removal.
The base unit operates on nominal 380/460 volt, 3

phase, 50/60 hertz power. An optional autotransformer

may be fitted to allow operation on nominal 190/230 , 3

phase, 50/60 hertz power. Power for the control system

is provided by a transformer which steps the supply

power down to 18 and 24 volts, single phase.
The controller is a Carrier Transicold Micro-Link 2i

microprocessor.

The

controller

will

operate

automatically to select cooling, holding or heating as

required to maintain the desired set point temperature

within very close limits.
The controller is fitted with a keypad and display for

viewing or changing operating parameters. The display

is also equipped with lights to indicate various modes of

operation.

1.2 CONFIGURATION IDENTIFICATION

Unit identification information is provided on a model

plate located to the left of the economizer. The plate

provides the unit model number and the unit parts

identification number (PID). The model number

identifies the overall unit configuration while the PID

provides information on specific optional equipment,

factory provision to allow for field installation of

optional equipment and differences in detailed parts.
Configuration identification for the models covered

herein are provided in the Carrier Transicold Container

Unit Matrix manual, publication T--300. Printed copies

of the T--300 may be obtained from Carrier Transicold.

Also, a weekly updated copy may be found at the Carrier

Web site, www.carrier.refrigeration.com.

1.3 OPTION DESCRIPTIONS

Various options may be factory or field fitted to the base

unit. Brief descriptions of the options are provided in

the following subparagraphs.

1.3.1 Battery

The controller may be fitted with standard replaceable

batteries or a rechargeable battery pack.

1.3.2 Dehumidification

The unit may be fitted with a humidity sensor. This

sensor allows setting of a humidity set point in the

controller. In the dehumidification mode the controller

will operate to reduce internal container moisture level.

1.3.3 Control Box

The control box is constructed of composite material

and may be fitted with a lockable door.

1.3.4 Temperature Readout

The unit may be fitted with suction and discharge

temperature sensors. The sensor readings may be

viewed on the controller display.

1.3.5 Pressure Readout

The unit may be fitted with factory installed suction and

discharge pressure gauges. The unit is fitted with

suction and discharge transducers. The readings may be

viewed on the controller display.

1.3.6 Interrogator

Units that use the DataCORDER function are fitted with

interrogator receptacles for connection of equipment to

download the recorded data. Two receptacles may be

fitted, one accessible from the front of the unit and the

other mounted inside the container (with the USDA

receptacles).

1.3.7 Remote Monitoring

The unit may be fitted with a remote monitoring

receptacle. This item allows connection of remote

indicators for COOL, DEFROST and IN RANGE.

1.3.8 Communications

The unit may be fitted with a communications interface

module. The communications interface module is a

slave module which allows communication with a

master central monitoring station. The module will

respond to communication and return information over

the main power line. Refer to the ship master system

technical manual for further information.

1.3.9 Compressor

The unit is fitted with a scroll compressor.

1.3.10 Back Panels

Back panel designs that may be fitted include panels of

aluminum and stainless steel. Panels may be fitted with

access doors and/or hinge mounting.

Advertising