Carrier Streamline Scroll 69NT20-531-300 User Manual

Page 33

Advertising
background image

3-8

T-309

Table 3-2 DataCORDER Configuration Variables

CONFIGURATION NO.

TITLE

DEFAULT

OPTION

dCF01

(Future Use)

----

----

dCF02

Sensor Configuration

2

2,5,6,9,54,64,94

dCF03

Logging Interval (Minutes)

60

15,30,60,120

dCF04

Thermistor Format

Short

Low, Normal

dCF05

Thermistor Sampling Type

A

A,b,C

dCF06

Controlled Atmosphere/Humidity Sampling Type

A

A,b

dCF07

Alarm Configuration USDA Sensor 1

A

Auto, On, Off

dCF08

Alarm Configuration USDA Sensor 2

A

Auto, On, Off

dCF09

Alarm Configuration USDA Sensor 3

A

Auto, On, Off

dCF10

Alarm Configuration Cargo Sensor

A

Auto, On, Off

b. Configuration Software

The configuration software controls the recording and

alarm functions of the DataCORDER. Reprogramming

to the factory installed configuration is achieved via the

same configuration card as the unit control module

software. Changes to the unit DataCORDER

configuration may be made made using the Data View

integration device. A listing of the configuration

variables is provided in Table 3-2. Descriptions of

DataCORDER operation for each variable setting are

provided in the following paragraphs.

3.6.3 Sensor Configuration (dCF02)

Two modes of operation may be configured, the

Standard Mode and the Generic Mode.

a. Standard Mode

In the standard mode, the user may configure the

DataCORDER to record data using one of seven

standard configurations. Standard configuration

variables, with descriptions, are listed in Table 3-3.

The six thermistor inputs (supply, return, USDA #1, #2,

#3 and cargo probe) and the humidity sensor input will

be generated by the DataCORDER. An example of a

report using a standard configuration is shown in

Figure 3- 5.

NOTE

The DataCORDER software uses the supply

and return recorder sensors (SRS,RRS). The
temperature control software uses the supply
and return temperature sensors (STS,RTS) .

b. Generic Mode

The generic recording mode allows user selection of the

network data points to be recorded. The user may select

up to a total of eight data points for recording. A list of

the data points available for recording follows.

Changing the configuration to generic and selecting

which data points to record may be done using the

Carrier Transicold Data Retrieval Program.

1. Control mode

2. Control temperature

3. Frequency

4. Humidity

5. Phase A current

6. Phase B current

7. Phase C current

8. Main voltage

9. Suction modulation valve percentage

10. Discrete outputs (Bit mapped -- require special

handling if used)

11. Discrete inputs (Bit mapped -- require special

handling if used)

12. Ambient sensor

13. Compressor suction sensor

14. Compressor discharge sensor

15. Return temperature sensor

16. Supply temperature sensor

17 Defrost temperature sensor

18. Discharge pressure transducer

19. Suction pressure transducer

20. Condenser pressure transducer

Table 3-3 DataCORDER Standard Configurations

Standard

Config.

Description

2 sensors

(dCF02=2) 2 thermistor inputs(supply & return)

5 sensors

(dCF02=5)

2 thermistor inputs(supply & return)

3 USDA thermistor inputs

6 sensors

(dCF02=6)

2 thermistor inputs(supply & return)

3 USDA thermistor inputs

1 humidity input

9 sensors

(dCF02=9) Not Applicable

6 sensors

(dCF02=54)

2 thermistor inputs(supply & return)

3 USDA thermistor inputs

1 cargo probe (thermistor input)

7 sensors

(dCF02=64)

2 thermistor inputs(supply & return)

3 USDA thermistor inputs

1 humidity input

1 cargo probe (thermistor input)

10 sensors

(dCF02=94

)

2 thermistor inputs(supply & return)

3 USDA thermistor inputs

1 humidity input

1 cargo probe (thermistor input)

3 C.A. inputs (NOT APPLICABLE)