2-5

2.1.6 Control Box Section

The control box (Figure 2-5) includes the manual

operation switches; circuit breaker (CB-1); compressor,

fan and heater contactors; control power transformer;

fuses; key pad; display module; current sensor module;

controller module expansion module and the

communications interface module.

2.1.7 Communications Interface Module

The communications interface module is a slave

module which allow communication with a master

central monitoring station. The module will respond to

communication and return information over the main

power line. Refer to the master system technical manual

for further information.

19

20

15

17

18

1

2

3

4

5

6

7

10 9

11

14

8

12

13

16

1. Compressor Phase A Contactor

2. Compressor Phase B Contactor

3. Heater Contactor

4. Display Module

5. Communications Interface Module

6. Controller/DataCORDER Module (Controller)

7. Expansion Module

8. Key Pad

9. Start-Stop Switch

10. Remote Monitoring Receptacle

11. Manual Defrost Switch

12. Condenser Fan Switch

13. Controller Battery Pack

14. Interrogator Connector (Box Location)

15. Control Transformer

16. Evaporator Fan Contactor - High

17. Evaporator Fan Contactor - Low

18. Condenser Fan Contactor

19. Circuit Breaker -- 460V

20. Current Sensor Module

Figure 2-5 Control Box Section