T-309

Safety-3

CAUTION

When Pre-Trip key is pressed, economy, dehumidification and bulb mode will be deactivated. At the

completion of Pre-Trip activity, economy, dehumidification and bulb mode must be reactivated.

CAUTION

When a failure occurs during automatic testing the unit will suspend operation awaiting operator in-

tervention.

CAUTION

When Pre--Trip test Auto 2 runs to completion without being interrupted, the unit will terminate pre-

trip and display “Auto 2” “end.” The unit will suspend operation until the user depresses the ENTER

key!

CAUTION

To prevent trapping liquid refrigerant in the manifold gauge set be sure set is brought to suction pres-

sure before disconnecting.

CAUTION

The scroll compressor achieves low suction pressure very quickly. Do not use the compressor to evacu-

ate the system below zero psig. Never operate the compressor with the suction or discharge service

valves closed (frontseated). Internal damage will result from operating the compressor in a deep vacu-

um.

CAUTION

Use only Carrier Transicold approved Polyol Ester Oil (POE) -- Mobil ST32 compressor oil with

R-134a. Buy in quantities of one quart or smaller. When using this hygroscopic oil, immediately reseal.

Do not leave container of oil open or contamination will occur.

CAUTION

Take necessary steps (place plywood over coil or use sling on motor) to prevent motor from falling into

condenser coil.

CAUTION

DO NOT disassemble piston from NEW suction modulating valve powerhead assembly. Doing so may

result in damage to piston.

CAUTION

The unit must be OFF whenever a programming card is inserted or removed from the controller pro-

gramming port.

CAUTION

Do not allow moisture to enter wire splice area as this may affect the sensor resistance.