1. Controller Software

Programming Port

2. Mounting Screw

3. Controller

4. Expansion Module

5. Test Points

Figure 6-18 Controller Section of the Control Box

a. Obtain a grounding wrist strap (Carrier Transicold

part number 07--00--304--00)and a static dissipation

mat (Carrier Transicold part number 07--00304--00.

The wrist strap, when properly grounded, will dissi-

pate any potential buildup on the body. The dissipa-

tion mat will provide a static-free work surface on

which to place and/or service the modules.

b. Disconnect and secure power to the unit.
c. Place strap on wrist and attach the ground end to any

exposed unpainted metal area on the refrigeration

unit frame (bolts, screws, etc.).

d. Carefully remove the module. Do not touch any of the

electrical connections if possible. Place the module

on the static mat.

e. The strap should be worn during any service work on

a module, even when it is placed on the mat.

6.21.2 Controller Trouble-Shooting

A group of test points (TP, see Figure 6-18) are provided

on the controller for trouble-shooting electrical circuits

(see schematic diagram, section 7). A description of the

test points follows:

NOTE

Use a digital voltmeter to measure ac voltage
between TP’s and ground (TP9), except for
TP8.

TP1

This test point enables the user to check if the controller

unloader solenoid valve relay (TU) is open or closed.

TP2

This test point enables the user to check if the high

pressure switch (HPS) is open or closed.

TP3

This test point enables the user to check if the water

pressure switch (WP) contact is open or closed.

TP 4

This test point enables the user to check if the internal

protector for the condenser fan motor(IP-CM) is open or

closed.

TP 5

This test point enables the user to check if the internal

protectors for the evaporator fan motors (IP-EM1 or

IP-EM2) are open or closed.

TP 6

This test point is not used in this application.

TP 7

This test point enables the user to check if the controller

economizer solenoid valve relay (TS) is open or closed

TP 8

This test point enables the user to check power to the

suction modulator valve.

TP 9

This test point is the chassis (unit frame) ground

connection.

TP 10

This test point enables the user to check if the heat

termination thermostat (HTT) contact is open or closed.

6.21.3 Controller Programming Procedure

To load new software into the module, the programming

card is inserted into the programming/software port.

CAUTION

The unit must be OFF whenever a program-

ming card is inserted or removed from the

controller programming port.

NOTE

The metal door on the programming card must
be facing to the left when inserting.

a. Procedure for loading Operational Software
1. Turn unit OFF, via start-stop switch (ST).
2. Insert the programming card for Operational Soft-

ware into the programming/software port. (See

Figure 6-18)

3. Turn unit ON, via start-stop switch (ST).
4. The Display module will alternate back and forth

between the messages “rEV XXXX” and “Press

EntR”. (If a defective card is being used the Display

will blink the message “bAd CArd”. Turn start-stop

switch OFF and remove the card.)