Carrier Streamline Scroll 69NT20-531-300 User Manual

Page 63

Advertising
background image

5-4

T-309

CONDITION

POSSIBLE CAUSE

REMEDY/

REFERENCE

SECTION

5.9 CONTROLLER MALFUNCTION

Defective Sensor

6.22

Defective wiring

Check

Will not control

Fuse (F1, F2, F3) blown

Replace

Will not control

Stepper motor suction modulation valve circuit malfunction 6.20
Low refrigerant charge

6.7

5.10 NO EVAPORATOR AIR FLOW OR RESTRICTED AIR FLOW

Evaporator coil blocked

Frost on coil

5.6

Evaporator coil blocked

Dirty coil

6.15

Evaporator fan motor internal protector open

6.17

No or partial evaporator air flow

Evaporator fan motor(s) defective

6.17

No or partial evaporator air flow

Evaporator fan(s) loose or defective

6.17

Evaporator fan contactor defective

Replace

5.11 THERMOSTATIC EXPANSION VALVE MALFUNCTION

Low refrigerant charge

6.7.1

External equalizer line plugged

Open

Wax, oil or dirt plugging valve or orifice Ice formation at

valve seat

6.14

Low suction pressure with high

s perheat

Superheat not correct

6.7.1

superheat

Power assembly failure
Loss of element/bulb charge

6 14

Broken capillary

6.14

Foreign material in valve

Hi h

i

i h l

Superheat setting too low

6.14

High suction pressure with low

superheat

External equalizer line plugged Ice holding valve open

Open

superheat

Foreign material in valve

6.14

Liquid slugging in compressor

Pin and seat of expansion valve eroded or held open by for-

eign material

6 14

Fluctuating suction pressure

Improper bulb location or installation

6.14

Fluctuating suction pressure

Low superheat setting

5.12 AUTOTRANSFORMER MALFUNCTION

Unit will not start

Circuit breaker (CB-1 or CB-2) tripped

Check

Unit will not start

Power source not turned ON

Check

5.13 WATER-COOLED CONDENSER OR WATER PRESSURE SWITCH

Condenser fan starts and stops

Water pressure switch malfunction

Check

Condenser fan starts and stops

Water supply interruption

Check