T-309

Table 3-4 Controller Configuration Variables

NOTES

1. Configuration numbers not listed are not used in this application. These items may appear when loading

configuration software to the controller but changes will not be recognized by the controller programming.

CONFIGURATION

NUMBER

TITLE

DEFAULT

OPTION

CnF02

Evaporator Fan Speed

dS (Dual)

SS (Single)

CnF04

Dehumidification Mode

On

OFF

CnF11

Defrost “Off” Selection

noOFF

OFF

CnF16

DataCORDER Present

On (Yes)

OFF (No)

CnF22

Economy Mode Option

OFF

Std, Full

CnF23

Defrost Interval Timer Save Option

noSAv

SAv

CnF24

Long Pre Trip Test Sequence Enabled

On

Off

CnF25

Pre-Trip Test Points/Results Recording Option

rSLtS

dAtA

CnF26

Heat Lockout Change Option

Set to --10_C

Set to --5_C

CnF28

Bulb Mode Option

NOr

bULb

CnF31

Probe Check Option

Std

SPEC

CnF33

Snap Freeze Option

OFF

SnAP

CnF34

Degree Celsius Lockout Option

bOth

_

F

CnF37

Electronic Temperature Recorder

rEtUR (Return)

suPPl, BOth

Advertising