Carrier Streamline Scroll 69NT20-531-300 User Manual

Page 27

Advertising
background image

3-2

T-309

3.1.1 Key Pad

The key pad (Figure 3- 2) is mounted on the right-hand

side of the control box. The key pad consists of eleven

push button switches that act as the user’s interface with

the controller. Descriptions of the switch functions are

provided in Table 3-1.

ENTER

BATTERY

POWER

DEFROST
INTERVAL

CODE

SELECT

PRE

TRIP

ALARM

LIST

ALT.

MODE

RETURN

SUPPLY

_

C

_

F

Figure 3- 2 Key Pad

COOL

HEAT DEFROST IN RANGE ALARM

SUPPLY RETURN

SETPOINT/Code

AIR TEMPERATURE/Data

Figure 3- 3 Display Module

3.1.2 Display Module

The display module (Figure 3- 3) consists of two

backlighted five digit LCD displays and seven indicator

lights. The indicator lights include:
1. Cool -- White LED: Energized when the refrigerant

compressor is energized.

2. Heat -- Orange LED: Energized to indicate heater op-

eration in the heat or defrost mode.

3. Defrost -- Orange LED: Energized when the unit is in

the defrost mode.

4. In-Range -- Green LED: Energized when the con-

trolled temperature probe is within specified toler-

ance of set point.

Table 3-1 Key Pad Function

KEY

FUNCTION

Code Select Accesses function codes.

Pre-Trip

Displays the pre-trip selection menu. Dis-

continues pre-trip in progress.

Alarm List Displays alarm list and clears the alarm

queue.

Defrost

Interval

Displays selected defrost interval.

Enter

Confirms a selection or saves a selection

to the controller.

Arrow Up

Change or scroll a selection upward Pre-

trip advance or test interruption.

Arrow

Down

Change or scroll a selection downward.

Pre-trip repeat backward.

Return/

Supply

Displays non-controlling probe tempera-

ture (momentary display).

_

C/_F

Displays alternate English/Metric scale

(momentary display). When set to _F,

pressure is displayed in psig and vacuum

in “/hg. “P” appears after the value to in-

dicate psig and “i” appears for inches of

mercury.
When set to _C. pressure readings are in

bars. “b” appears after the value to indi-

cate bars.

Battery

Power

Initiate battery backup mode to allow set

point and function code selection if AC

power is not connected.

ALT Mode

This key is pressed to switch the functions

from the temperature software to the Da-

taCORDER Software. The remaining keys

function the same as described above ex-

cept the readings or changes are made to

the DataCORDER programming..

NOTE

The controlling probe in the perishable range

will be the SUPPLY air probe and the control-
ling probe in the frozen range will be the
RETURN air probe.

5. Supply -- Yellow LED: Energized when the supply air

probe is used for control. When this LED is illumi-

nated, the temperature displayed in the AIR TEMPER-

ATURE display is the reading at the supply air probe.

This LED will flash if dehumidification or humidifi-

cation is enabled.

6. Return -- Yellow LED: Energized when the return air

probe is used for control. When this LED is illumi-

nated, the temperature displayed in the AIR TEM-

PERATURE display is the reading at the return air pro-

be. This LED will flash if dehumidification or

humidification is enabled.

7. Alarm -- Red LED: Energized when there is an active

or an inactive shutdown alarm in the alarm queue