3-25

T-309

Table 3-8 DataCORDER Function Code Assignments

NOTE

Inapplicable Functions Display “

-- -- -- -- --”

To Access: Press ALT. MODE key

Code

No.

TITLE

DESCRIPTION

dC1

Recorder Supply

Temperature

Current reading of the supply recorder sensor.

dC2

Recorder Return

Temperature

Current reading of the return recorder sensor.

dC3-5

USDA 1,2,3 Tem-

peratures

Current readings of the three USDA probes.

dC6-13 Network Data

Points 1-8

Current values of the network data points (as configured). Data point 1 (Code

6) is generally the humidity sensor and its value is obtained from the Control-

ler once every minute.

dC14

Cargo Probe 4 Tem-

perature

Current reading of the cargo probe #4.

dC15-19 Future Expansion

These codes are for future expansion, and are not in use at this time.

dC20-24 Temperature Sensors

1-5 Calibration

Current calibration offset values for each of the five probes: supply, return,

USDA #1, #2, and #3. These values are entered via the interrogation pro-

gram.

dC25

Future Expansion

This code is for future expansion, and is not in use at this time..

dC26,27 S/N, Left 4, Right 4

The DataCORDER serial number consists of eight characters. Function code

dC26 contains the first four characters. Function code dC27 contains the last

four characters. (This serial number is the same as the Controller serial num-

ber)

dC28

Minimum Days Left An approximation of the number of logging days remaining until the Data-

CORDER starts to overwrite the existing data.

dC29

Days Stored

Number of days of data that are currently stored in the DataCORDER.

dC30

Date of last Trip

start

The date when a Trip Start was initiated by the user. In addition, if the system

goes without power for seven continuous days or longer, a trip start will auto-

matically be generated on the next AC power up.

dC31

Battery Test

Shows the current status of the optional battery pack.

PASS: Battery pack is fully charged.

FAIL: Battery pack voltage is low.

dC32

Time: Hour, Minute Current time on the real time clock (RTC) in the DataCORDER.

dC33

Date: Month, Day

Current date (month and day) on the RTC in the DataCORDER.

dC34

Date: Year

Current year on the RTC in the DataCORDER.

dC35

Cargo Probe 4

Calibration

Current calibration value for the Cargo Probe. This value is an input via the

interrogation program.

Advertising