Carrier Streamline Scroll 69NT20-531-300 User Manual

Page 40

Advertising
background image

3-15

T-309

Table 3-5 Controller Function Codes (Sheet 2 of 3)ff

Cd22 Compressor State

The status of the compressor is displayed (Off, On).

Cd23 Evaporator Fan

Displays the current evaporator fan state (high, low or off).

Cd24 Controlled

Atmosphere State

Not used in this application

Cd25

Compressor Run

Time Remaining

Until Defrost

This code displays the time remaining until the unit goes into defrost (in tenths of

an hour). This value is based on the actual accumulated compressor running time.

Cd26 Defrost Temperature

Sensor Reading

Defrost temperature sensor reading is displayed.

Configurable Functions

NOTE

Function codes Cd27 through Cd37 are user-selectable functions. The operator can change the value of

these functions to meet the operational needs of the container.

Cd27 Defrost Interval

(Hours)

The defrost interval is the time between defrost cycles. Five selectable values are

available: 3, 6, 9, 12 or 24 hours. The factory default value is 12 hours. Follow-

ing a start--up or after termination of a defrost, the time will not begin counting

down until the defrost temperature sensor (DTS) reading falls below set point. If

the reading of DTS rises above set point any time during the timer count down,

the interval is reset and the countdown begins over. If DTS fails, alarm code

AL60 is activated and control switches over to the the return temperature sensor.

The controller will act in the same manner as with the DTS except the return tem-

perature sensor reading will be used.

Defrost Interval Timer Value (Configuration variable CnF23): If the software is

configured to “SAv” (save) for this option, then the value of the defrost interval

timer will be saved at power down and restored at power up. This option prevents

short power interruptions from resetting an almost expired defrost interval, and

possibly delaying a needed defrost cycle.

NOTE

The defrost interval timer counts only during compressor run time.

Cd28 Temperature Units

(_C or _F)

This code determines the temperature units (_C or _F) which will be used for all

temperature displays. The user selects _C or _F by selecting function code Cd28

and pushing the ENTER key. The factory default value is Celsius units.

NOTE

This function code will display “

--- --- --- --- ---“ if Configuration Variable

CnF34 is set to _F.

Cd29 Failure Action

(Mode)

If all of the control sensors are out of range (alarm code AL26) or there is a probe

circuit calibration failure (alarm code AL27), the unit will enter the shutdown

state defined by this setting. The user selects one of four possible actions as fol-

lows:

A -- Full Cooling (compressor is on, economized operation. SMV subject to pressure

and current limit.)

B -- Partial Cooling (Compressor is on, standard operation. SMV subject to pressure

and current limit.)

C -- Evaporator Fan Only (Compressor is off, evaporator fans on high speed, not ap-

plicable with frozen set points.

D -- Full System Shutdown -- Factory Default (shut down every component in the

unit)

Cd30 In-Range Tolerance

The in-range tolerance will determine the band of temperatures around the set

point which will be designated as in-range. If the control temperature is in-range,

the in-range light will be illuminated. There are four possible values:

1 = ¦ 0.5_C (¦ 0.9_F)

2 = ¦ 1.0_C (¦ 1.8_F)

3 = ¦ 1.5_C (¦ 2.7_F)

4 = ¦ 2.0_C (¦ 3.6_F) -- Factory Default

Advertising