RX Out-of-Band Flow Control Signals

The receive out-of-band flow control interface receives input flow-control clock, data, and sync signals

and sends out calendar and status information. The RX Out-of-Band Flow Control Interface Signals table

describes the receive out-of-band flow control interface signals specified in the Interlaken Protocol Specifi‐

cation, Revision 1.2. The RX Out-of-Band Flow Control Block Signals for Application Use describes the

signals on the application side of the RX out-of-band flow control block.

Table 10-4: RX Out-of-Band Flow Control Interface Signals

Signal Name

Direction

Width

(Bits)

Description

fc_clk

Input

1

Input reference clock from an upstream out-of-band TX block. This

signal clocks the

fc_data

and

fc_sync

signals. You must connect this

signal to a device pin.

fc_data

Input

1

Input serial data pin from an upstream out-of-band TX block. You

must connect this signal to a device pin.

fc_sync

Input

1

Input sync control pin from an upstream out-of-band TX block. You

must connect this signal to a device pin.

Table 10-5: RX Out-of-Band Flow Control Block Signals for Application Use

Signal Name

Direction

Width

(Bits)

Description

sys_clk

Input

1

Reference clock for capturing RX calendar, lane status,

and link status. Frequency must be at least double the

frequency of the TX

fc_clk

input clock.

sys_arst

Input

1

Asynchronous reset for the out-of-band RX block.

status_update

Output

1

Indicates a new value without CRC4 errors is present on

at least one of

lane_status

or

link_status

in the

current

sys_clk

cycle. The value is ready to be read by

the application logic.

lane_status

Output

Number of

Lanes

Lane status bits received from an upstream out-of-band

TX block on

fc_data

. Width is the number of lanes.

link_status

Output

1

Link status bit received from an upstream out-of-band

TX block on

fc_data

.

status_error

Output

1

Indicates corrupt lane or link status. A new value is

present on at least one of

lane_status

or

link_status

in the current

sys_clk

cycle, but the value has at least

one CRC4 error.

10-4

RX Out-of-Band Flow Control Signals

UG-01128

2015.05.04

Altera Corporation

Out-of-Band Flow Control in the 100G Interlaken MegaCore Function