Advanced Parameter Settings

9

2015.05.04

UG-01128

Subscribe

Send Feedback

Advanced users can further customize the 100G Interlaken IP core by modifying hidden parameters that

are not displayed in the 100G Interlaken parameter editor. These parameters can only be modified in the

Verilog RTL instantiation in the generated

ilk_core.sv

file and the instantiation of the 100G Interlaken IP

core in the top level design file.
The following topics describe the hidden parameters and tell you how to modify their values.

Hidden Parameters

on page 9-1

Modifying Hidden Parameter Values

on page 9-3

Hidden Parameters

The advanced parameters affect the behavior of the 100G Interlaken MegaCore function.
Note: Altera recommends that you do not modify any RTL parameters that are not listed here. Some

undocumented modifications might overwrite settings you specify in the parameter editor.

To customize your 100G Interlaken MegaCore function, you can modify parameters to specify the

following properties:

Include Temp Sense

on page 9-1

RXFIFO Address Width

on page 9-2

SWAP_TX_LANES and SWAP_RX_LANES (Data Word Lane Swapping)

on page 9-2

Include Temp Sense

The Include Temp Sense parameter specifies whether the IP core includes logic to sense the device’s case

temperature. If the value is set to 1, the IP core is configured with internal temperature sensing. If the

value is set to 0, this logic is synthesized away.
This parameter is not available in IP core variations that target an Arria 10 device.
The default value of this parameter is 1.

Related Information

Modifying Hidden Parameter Values

on page 9-3

©

2015 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are

trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as

trademarks or service marks are the property of their respective holders as described at

www.altera.com/common/legal.html

. Altera warrants performance

of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any

products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,

product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device

specifications before relying on any published information and before placing orders for products or services.

ISO

9001:2008

Registered

www.altera.com

101 Innovation Drive, San Jose, CA 95134

Advertising