The 100G Interlaken MegaCore function value for the Interlaken BurstMax parameter is determined by

the value you specify on the

burst_max_in

input signal. The 100G Interlaken MegaCore function

supports three values for BurstMax, 128 bytes, 256, and 512 bytes.
Note: You should only modify the value of the

burst_max_in

signal when no traffic is present.

You can configure your 100G Interlaken MegaCore function to use 1, 2, 4, 8, or 16 pages of 16 calendar

bits. The application determines the use of the in-band flow control bits that the MegaCore function

receives on the incoming Interlaken link, and the application is responsible for specifying the values of the

in-band flow control bits the MegaCore function transmits on the outgoing Interlaken link.

Related Information

100G Interlaken IP Core Interlaken Link and Miscellaneous Interface Signals

on page 5-9

Information about setting the BurstMax and BurstShort values, including the encoding of your desired

value on the

burst_max_in

or

burst_short_in

input signal.

100G Interlaken IP Core User Data Transfer Interface Signals

on page 5-4

Information about the in-band flow control signals that you control and view on the application

interface.

Interlaken Protocol Specification, Revision 1.2

Available from the Interlaken Alliance web site at www.interlakenalliance.com.

Out‑of‑Band Flow Control Interface

The optional out-of-band flow control interface conforms to the out-of-band requirements in Section

5.3.4.2, Out-of-Band Flow Control, of the Interlaken Protocol Specification, Revision 1.2.

Related Information

Out-of-Band Flow Control in the 100G Interlaken MegaCore Function

on page 10-1

Interlaken Protocol Specification, Revision 1.2

Available from the Interlaken Alliance web site at www.interlakenalliance.com.

Management Interface

The management interface provides access to the 100G Interlaken IP core internal status and control

registers. This interface does not provide access to the hard PCS registers on the device.
The management interface complies with the Avalon Memory-Mapped (Avalon-MM) specification

defined in the Avalon Interface Specifications.

Related Information

Avalon Interface Specifications

Transceiver Control Interfaces

The 100G Interlaken IP core provides several interfaces to control the transceiver. The transceiver control

interfaces in your 100G Interlaken IP core variation depend on the device family the variation targets.
The 100G Interlaken IP core supports the following transceiver control interfaces:

Transceiver Reconfiguration Controller Interface

on page 4-3

Arria 10 External PLL Interface

on page 4-3