Altera 100G Interlaken MegaCore Function User Manual

Page 70

Advertising
background image

Signal Name

Direction

Width (Bits)

Description

crc24_err

Output

1

A CRC24 error flag covering both control word

and data word. This signal does not associate

the CRC24 error with a particular packet.

Instead, its value indicates the overall SERDES

status. You can use this signal to count the

number of CRC24 errors.
This signal is asserted as a single cycle wide

pulse. If the IP core detects back-to-back

CRC24 errors, this signal toggles.

crc32_err

Output

Number of lanes

An error flag indicating diagnostic CRC32

failures per lane. This signal is asserted as a

single cycle wide pulse. If back-to-back CRC32

errors are detected, this signal toggles.

irx_overflow

Output

1

An error flag indicating the presence of

excessive jitter at the receiver side. This signal is

included in the current IP core opportunisti‐

cally for diagnostic purposes.

rdc_overflow

Output

1

An error flag indicating that the RX domain-

crossing FIFO is currently overflowed. The RX

domain-crossing FIFO transfers data from the

PCS clock domain to the MAC clock domain.

rg_overflow

Output

1

An error flag indicating that the Reassembly

FIFO is currently overflowed. The Reassembly

FIFO is the receiver FIFO that feeds directly to

the user data interface.

rxfifo_fill_

level

Output

RXFIFO_ADDR_

WIDTH

The fill level of the Reassembly FIFO, in units of

64-bit words. The width of this signal is the

value of the RXFIFO_ADDR_WIDTH

parameter, which is 12 by default. You can use

this signal to monitor when the RX Reassembly

FIFO is empty.

sop_cntr_inc

Output

1

A pulse indicating that the 100G Interlaken IP

core receiver user data interface received a start-

of-packet. You can use this signal to increment

a count of SOPs the application observes on the

receive interface.

eop_cntr_inc

Output

1

A pulse indicating that the 100G Interlaken IP

core receiver user data interface received an

end-of-packet. You can use this signal to

increment a count of EOPs the application

observes on the receive interface.

5-12

100G Interlaken IP Core Interlaken Link and Miscellaneous Interface Signals

UG-01128

2015.05.04

Altera Corporation

100G Interlaken MegaCore Function Signals

Send Feedback

Advertising