Table 3-1: 100G Interlaken IP Core Supported Combinations of Number of Lanes and Data Rate

Yes indicates a supported combination.

Number of Lanes

Lane Rate (Gbps)

6.25

10.3125

12.5

12

Yes

Yes

24

Yes

Meta Frame Length in Words

The Meta frame length in words parameter specifies the length of the meta frame, in 64-bit (8-byte)

words. In the Interlaken specification, this parameter is called the MetaFrameLength parameter.
Smaller values for this parameter shorten the time to achieve lock. Larger values reduce overhead while

transferring data, after lock is achieved.
For simulation, you can set the Meta frame length in words parameter to the value of 128 for fast lane

locking. For hardware testing, Altera recommends that you set the Meta frame length in words

parameter to the value of 2048.
The default value of the Meta frame length in words parameter is 2048.

Data Rate

The Data Rate parameter specifies the data rate on each lane. All lanes have the same data rate (lane rate).
The default value of the Data Rate parameter is 10312.5 Mbps (10.3125 Gbps).
The 100G Interlaken MegaCore function supports various combinations of number of lanes and lane

rates. Ensure that your parameter settings specify a supported combination.

Table 3-2: 100G Interlaken IP Core Supported Combinations of Number of Lanes and Data Rate

Yes indicates a supported combination.

Number of Lanes

Lane Rate (Gbps)

6.25

10.3125

12.5

12

Yes

Yes

24

Yes

Transceiver Reference Clock Frequency

The Transceiver reference clock frequency parameter specifies the expected frequency of the

pll_ref_clk

input clock.