4

TECHNICAL FEATURES

4.1

EXTERNAL POWER SUPPLY

An external alternating current power supply comes with the unit. It may be used to power the
unit while recording or to recharge the battery.

Rated voltage

100…240 Vac

Power supply frequency

50…60 Hz

Output voltage

12 Vdc

Current

3.33 A

Max. power

40 W

4.2

AUXILIARY POWER SUPPLY

Rated voltage

12 Vdc

Current

2 A

Maximum power

24 W

Consumption

30 VA

4.3

BATTERY

The AR6 has a built-in Nickel-Metal Hydride battery for the unit's main power supply which gives
it autonomy of operation and logging. It also has another internal Lithium battery that
permanently powers the internal clock.

4.3.1 Rechargeable main power supply battery

BATTERY

NiMH (Nickel-Metal Hydride)

Voltage

6 V

Capacity

4,200 mAh

Charge time

2 to 3 h

Battery life while in use

4hrs with LCD on

8hrs with LCD off

4.3.2 Clock power supply internal battery

Lithium battery

CR2025

Voltage

3 V

Capacity

600 mA/h

Battery life without charging

10 years