233

 DVR and monitor resistance is not compatible.
 Video transmission is too long or degrading is too huge.
 DVR color or brightness setup is not correct.

6. Can not search local records.

There are following possibilities:

 HDD ribbon is damaged.
 HDD is broken.
 Upgraded program is not compatible.
 The recorded file has been overwritten.
 Record function has been disabled.

7. Video is distorted when searching local records.

There are following possibilities:

 Video quality setup is too low.
 Program read error, bit data is too small. There is mosaic in the full screen.

Please restart the DVR to solve this problem.

 HDD data ribbon error.
 HDD malfunction.
 DVR hardware malfunctions.

8. There is no audio when monitor.

There are following possibilities:

 It is not a power picker.
 It is not a power acoustics.
 Audio cable is damaged.
 DVR hardware malfunctions.

9. There is audio when monitor but there is no audio when system playback.

There are following possibilities:

 Setup is not correct. Please enable audio function
 Corresponding channel has no video input. Playback is not continuous when the

screen is blue.

10. Time display is not correct.

There are following possibilities:

 Setup is not correct
 Battery contact is not correct or voltage is too low.
 Crystal is broken.

11. DVR can not control PTZ.

There are following possibilities:

 Front panel PTZ error

Advertising