Table 16 Required configurations on ports of different link types for them to support tagged voice traffic

Port link

type

Voice VLAN

assignment mode

Support for tagged

voice traffic

Configuration requirements

Automatic

Access

Manual

No —

Automatic

The PVID of the port cannot be the voice VLAN.

Trunk

Manual

Yes

The PVID of the port cannot be the voice VLAN.
Configure the port to permit packets of the voice

VLAN to pass through.

Automatic

The PVID of the port cannot be the voice VLAN.

Hybrid

Manual

Yes

The PVID of the port cannot be the voice VLAN.
Configure the port to permit packets of the voice

VLAN to pass through tagged.

IP phones send untagged voice traffic

When IP phones send untagged voice traffic, you can only configure the voice traffic receiving ports on

the device to operate in manual voice VLAN assignment mode.

Table 17 Required configurations on ports of different link types for them to support tagged voice traffic

Port link

type

Voice VLAN

assignment mode

Support for untagged

voice traffic

Configuration requirements

Automatic No

Access

Manual Yes

Configure the PVID of the port as the voice
VLAN.

Automatic No

Trunk

Manual Yes

Configure the PVID of the port as the voice VLAN
and assign the port to the voice VLAN.

Automatic No

Hybrid

Manual Yes

Configure the PVID of the port as the voice VLAN
and configure the port to permit packets of the

voice VLAN to pass through untagged.

CAUTION:

If an IP phone sends tagged voice traffic and its accessing port is configured with 802.1X authentication
and guest VLAN, assign different VLAN IDs for the voice VLAN, the PVID of the connecting port, and
the 802.1X guest VLAN.

If an IP phone sends untagged voice traffic, to implement the voice VLAN feature, you must configure the
PVID of the IP phone’s accessing port as the voice VLAN. As a result, you cannot implement 802.1X

authentication.