NOTE:

When it calculates path cost for an aggregate interface, IEEE 802.1t takes into account the number of
Selected ports in its aggregation group, but IEEE 802.1d-1998 does not. The calculation formula of IEEE

802.1t is: Path cost = 200,000,000/link speed (in 100 kbps), where link speed is the sum of the link speed
values of the Selected ports in the aggregation group.

Table 14 Mappings between the link speed and the path cost

Path cost

Link speed

Port type

IEEE 802.1d-1998

IEEE 802.1t

Private standard

0 —

65535 200,000,000

200,000

Single port

2,000,000

2000

Aggregate interface
containing 2 Selected ports

1,000,000 1800

Aggregate interface
containing 3 Selected ports

666,666 1600

10 Mbps

Aggregate interface
containing 4 Selected ports

100

500,000 1400

Single port

200,000

200

Aggregate interface
containing 2 Selected ports

100,000 180

Aggregate interface
containing 3 Selected ports

66,666 160

100 Mbps

Aggregate interface
containing 4 Selected ports

19

50,000 140

Single port

20,000

20

Aggregate interface
containing 2 Selected ports

10,000 18

Aggregate interface
containing 3 Selected ports

6666 16

1000 Mbps

Aggregate interface
containing 4 Selected ports

4

5000 14

Single port

2000

2

Aggregate interface
containing 2 Selected ports

1000 1

Aggregate interface
containing 3 Selected ports

666 1

10 Gbps

Aggregate interface
containing 4 Selected ports

2

500 1

Configuring path costs of ports

Follow these steps to configure the path cost of ports: