Login overview, Hardware compatibility, Login methods at a glance – H3C Technologies H3C SecBlade LB Cards User Manual

Page 16

Advertising
background image

6

Login overview

This chapter describes the available login methods and their configuration procedures.

Hardware compatibility

Product AUX

port compatible

L1000-A

No

LB module

Yes (internal interface, used only for OAP connection to
the device holding the card)

Login methods at a glance

For the first login, you can connect a terminal to the console port of the LB product to access the CLI or
use the username admin and password admin to access the Web interface of the LB product. After login,

you can configure other login methods, such as Telnet and SSH for remote access.

Table 1 Login methods

Login method

Default setting and configuration requirements

Logging in to the CLI

:

Logging in through the console
port for the first time

By default, login through the console port is enabled, no username or
password is required, and the user privilege level is 3.

Logging in through Telnet

By default, Telnet service is disabled. To use Telnet service, complete
the following configuration tasks:

Enable the Telnet server function.

Assign an IP address to a Layer 3 interface and make sure the

interface and the Telnet client can reach each other. By default, the

LB module has the IP address 192.168.0.1/24 configured for the
interface GigabitEthernet 0/1 and L1000-A has the same IP

address configured for the interface GigabitEthernet 0/0.

Configure the authentication mode for VTY login users (scheme by

default).

Configure the user privilege level of VTY login users (0 by default).

Advertising