7

Login method

Default setting and configuration requirements

Logging in through SSH

By default, SSH service is disabled. To use SSH service, complete the
following configuration tasks:

Enable the SSH server function and configure SSH attributes.

Assign an IP address to a Layer 3 interface and make sure the

interface and the SSH client can reach each other. By default, the
LB module has the IP address 192.168.0.1/24 configured for the

interface GigabitEthernet 0/1 and L1000-A has the same IP

address configured for the interface GigabitEthernet 0/0.

Enable scheme authentication for VTY login users (scheme by

default).

Configure the user privilege level of VTY login users (0 by default).

Logging in to the Web interface

By default, you can log in to the Web interface with the IP address
192.168.0.1/24, username admin, and password admin. (By
default, the LB module has the IP address 192.168.0.1/24

configured for the interface GigabitEthernet 0/1 and L1000-A has the

same IP address configured for the interface GigabitEthernet 0/0.)

Logging in through SNMP

By default, SNMP login is disabled. To use SNMP service, complete
the following configuration tasks:

Assign an IP address to a Layer 3 interface, and make sure the

interface and the NMS can reach each other. By default, the LB

module has the IP address 192.168.0.1/24 configured for the
interface GigabitEthernet 0/1 and L1000-A has the same IP

address configured for the interface GigabitEthernet 0/0.

Configure SNMP basic parameters.

Logging in to the LB module from the
network device

When the LB module is inserted in a switch or router, you can use
OAA to log in to the LB module from the CLI of the switch or router.

CLI user interfaces

The LB product uses user interfaces (also called "lines") to control CLI logins and monitor CLI sessions.

You can configure access control settings, including authentication, user privilege, and login redirect on

user interfaces. After users are logged in, their actions must be compliant with the settings on the user
interfaces assigned to them.
Users are assigned different user interfaces, depending on their login methods, as shown in

Table 2

.

Table 2 CLI login method and user interface matrix

User interface

Login method

Console user interface

Console port (EIA/TIA-232 DCE)

AUX user interface

AUX port

Virtual type terminal (VTY) user interface

Telnet or SSH