To set modulating phase, To set modulating polarity – RIGOL DG1000Z Series User Manual

Page 103

Advertising
background image

Chapter 2 Front Panel Operations

RIGOL

DG1000Z User’s Guide

2-53

To Set Modulating Phase

Press Phase to set the modulating phase.
 Use the numeric keyboard or direction keys and knob to input the desired phase

value.

 The phase range is from 0° to 360° and the default is 180°.

To Set Modulating Polarity

Press Polarity to select the “Pos” or “Neg” polarity of the modulating waveform to

control the output phase.

In internal modulation, set the polarity to “Pos” and the generator would output the

carrier phase when the modulating waveform is logic low level and output the

modulating phase when the modulating waveform is logic high level. The situation is

the opposite when the polarity is set to “Neg”.

In external modulation, set the polarity to “Pos” and the generator would output the

carrier phase when the external input signal is logic low level and output the

modulating phase when the external input signal is logic high level. The situation is

the opposite when the polarity is set to “Neg”.

Advertising