Example: to output harmonic, Example: to output harmonic -33 – RIGOL DG1000Z Series User Manual

Page 83

Advertising
background image

Chapter 2 Front Panel Operations

RIGOL

DG1000Z User’s Guide

2-33

Example: To Output Harmonic

This section introduces how to output 2th order of harmonic (harmonic amplitude:

2Vpp, harmonic phase: 30°) and 4th orders of harmonic (harmonic amplitude: 1Vpp,

harmonic phase: 50°) from the [CH1] connector. The fundamental waveform is the

default sine of the instrument and the harmonic order is 5.

1. To Select Output Channel: Press CH1|CH2 to select CH1. At this time, the

border of the channel status bar is displayed in yellow.

2. To Set Fundamental Waveform Parameters: In this example, various

parameters of the fundamental waveform take the default values. You can also

refer to the introduction in To Output Basic Waveform to set various

fundamental waveform parameters such as frequency/period, amplitude/high

level, offset/low level and start phase.

3. To Enable Harmonic Function: Press Sine

Harm to select “On” and press

Harmonic Para to enter the harmonic setting menu.

4. To Set Harmonic Order: In the harmonic setting menu, press Order and use

the numeric keyboard to input 5 before pressing OK.

5. To Select Harmonic Type: In the harmonic setting menu, press Type to

select even harmonic.

6. To Select Harmonic Amplitude: In the harmonic setting menu, press

Harmonic Ampl to successively set the amplitude of 2th and 4th orders of

harmonic.

1) Press SN, input 2 (the harmonic sequence number) using the numeric

keyboard, and press OK.

2) Press Harmonic Ampl, input 2 (the value of the amplitude) using the

numeric keyboard, and select the unit “Vpp” from the pop-up units menu.

3) Refer to step 1 and 2 to set the amplitude of the 4th order harmonic to

1Vpp.

7. To Set Harmonic Phase: In the harmonic setting menu, press Harmonic

Phase to set the phase of 2th and 4th orders of harmonic successively.

1) Press SN, input 2 (the harmonic sequence number) using the numeric

keyboard, and press OK.

2) Press Harmonic Phase, input 30 (the value of the phase) using the

numeric keyboard, and select the unit “°” from the pop-up units menu.

3) Refer to step 1 and 2 to set the phase of the 4th order harmonic to 50°.

Advertising