4 wiring the power inputs – PLANET ISW-1022MPT User Manual

Page 33

Advertising
background image

User’s Manual of ISW-1022M Series and ISW-1033MT

33

2.2.4 Wiring the Power Inputs

The 6-contact terminal block connector on the top panel of ISW-1022M series is used for two DC redundant power input.

Please follow the steps below to insert the power wire.

1. Insert positive / negative DC power wires into the contacts 1 and 2 for POWER 2, or 5 and 6 for POWER 1.

Figure 2-12

Wiring the redundant power inputs

2. Tighten the wire-clamp screws for preventing the wires from loosing.

1 2 3 4 5 6

Power 2

Power 1

- + - +

Figure 2-13

6-Pin Terminal Block power wiring input

The wire gauge for the terminal block should be in the range between 12 ~ 24 AWG.

Advertising
This manual is related to the following products: