User’s Manual of ISW-1022M Series and ISW-1033MT

43

4.3 Login in the Console Interface

To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to RJ-45 type serial
(console) port of the Managed Industrial Switch. The console port of the Managed Industrial Switch is DCE already, so
that you can connect the console port directly through PC without the need of Null Modem.

A terminal program is required to make the software connection to the ISW Managed Industrial Switch. Windows' Hyper

Terminal

program may be a good choice. The Hyper Terminal can be accessed from the Start menu.

1. Click

START

, then Programs, Accessories and then Hyper Terminal.

2.

When the following screen appears, make sure that the COM port should be configured as:

Baud Rate: 9600 bps

Data Bits: 8

Parity: none

Stop Bit: 1

Flow control: None

The settings of communication parameters