Promise Technology VTrack M-Class M200i User Manual

Page 138

Advertising
background image

VTrak M-Class Product Manual

130

To create a new disk array:

1.

Click the Subsystem

icon in Tree View.

2.

Click on the Disk Arrays

icon.

3.

Click on the Create tab in Management View.

4.

From the Create tab dropdown menu, select Express.

5.

Check the boxes to select any one or combination of the following:

Redundancy – The array will remain available if a physical drive fails

Capacity – The greatest possible amount of data capacity

Performance – The highest possible read/write speed

Spare Drive – A hot spare drive is created when you select Redundancy,
Spare Drive, and five or more unconfigured physical drives are available

6.

In the Number of Logical Drives field, enter the number of logical drives you
want to make from this disk array.

7.

From the Application Type menu, select an application that best describes
your intended use for this disk array:

File Server

Video Stream

Transaction Data

Transaction Log

Other

8.

Click the Update button.

Or check the Automatic Update box and updates will occur automatically.

The following parameters display:

Disk Arrays – The number of physical drives in the disk array, their slot
numbers, configurable capacity, and the number of logical drives to be
created

Logical Drives – The slot number of the logical drive(s), their RAID level,
capacity, and stripe size

Spare Drives – The physical drive slot number of the dedicated hot
spare assigned to this disk array (all RAID levels except RAID 0)

If you accept these parameters, proceed to the next step.

If you do NOT accept these parameters, review and modify your selections
in the previous steps.

9.

When you are done, click the Submit button.

The new disk array appears in the Disk Array List on the Information tab.

Advertising