Chapter 5: Management with the CLU

213

Shutdown and Restart

This function enables you to shutdown or restart the VTrak subsystem. You can
only do part of this procedure in the CLU. Additional action is required, as
described below. What you see on the screen differs whether you have a Telnet
or serial connection.

Shutdown over Telnet

To shutdown the VTrak subsystem on a Telnet connection:

1.

From the Main Menu, highlight Additional Info and Management and press
Enter.

2.

Highlight Shutdown or Restart and press Enter.

3.

Press the spacebar to display Shutdown then press Enter.

A warning message appears.

4.

Press Y to continue.

The screen will go blank.

5.

Wait for no less than two minutes.

6.

Manually turn off the power supply switches on the back of the subsystem.

Shutdown over Serial

To shutdown the VTrak subsystem on a serial connection:

1.

From the Main Menu, highlight Additional Info and Management and press
Enter.

2.

Highlight Shutdown or Restart and press Enter.

3.

Press the spacebar to display Shutdown then press Enter.

A warning message appears.

4.

Press Y to continue”

5.

When this message appears:

Shutdown complete. It is now safe to power off

the subsystem.

turn off the power supply switches.

Restart over Telnet

To restart the VTrak subsystem on a Telnet connection:

1.

From the Main Menu, highlight Additional Info and Management and press
Enter.

2.

Highlight Shutdown or Restart and press Enter.

3.

Press the spacebar to display Restart then press Enter.

A warning message appears.