Chapter 8: Troubleshooting

285

Synchronization is
queued

Synchronization is already running on another logical
drive in the same array.

Synchronization is
stopped internally

Synchronization stopped because the disk array was
deleted or removed.

System (VTrak)

The system is started

The VTrak has been started.

The system is stopped

The VTrak was shut down.

Transition

Transition is started

Result of settings or user action. Normal.

Transition is completed

Normal.

Transition is paused

Transition paused because of user intervention,
schedule or a higher priority background activity.

Transition is resumed

Transition has resumed again after a pause.

Transition is stopped

Transition stopped because of user intervention or
the logical drive was deleted.

Transition was switched
to rebuild

Transition changed to rebuild because the logical
drive went critical.

Watermark

Migration has detected/
cleared stale NV
Watermark

Watermarks are progress markers left as the result of
interrupted RAID migrations. If the watermark was
cleared, migration should finish.

Array was incomplete due
to missing NV Watermark

RAID migration was interrupted by a shutdown. If
array is online, try migration again. See page 137. If
array is offline, delete and recreate array. See
page 132 and page 131.

Event

Action