Promise Technology VTrack M-Class M200i User Manual

Page 289

Advertising
background image

Chapter 8: Troubleshooting

281

PSU fan speed increased. Check the VTrak for overheating. See page 289.

PSU fan speed
decreased.

Temporary overheat condition was corrected.

PSU fan is malfunctioning Replace the power supply. See page 220.

PSU fan is functioning
normally

Normal.

PSU fan status is
unknown.

Check for airflow out of the power supply. If there is
none, check for proper installation and turn the power
supply on.

RAID Level Migration

RAID Level migration is
started

Result of settings or user action. Normal.

RAID Level migration is
completed

Normal.

RAID Level migration is
paused

Migration paused because of user intervention,
schedule or a higher priority background activity.

RAID Level migration is
resumed

Migration has resumed again after a pause.

RAID Level migration is
stopped

Migration stopped because of user intervention,
schedule or the logical drive was deleted or went
critical or offline.

RAID Level migration has
encountered a physical
disk error

Bad block found on a disk drive. Migration will finish.
Check the disk drive check table after migration and
replace disk drive as needed. See page 147.

RAID Level migration is
aborted due to an internal
error.

System resources are low. Reduce system load or
restart the VTrak. See page 218.

RAID Level migration is
queued

Migration has been set manually or by schedule.

Migration has detected/
cleared stale NV
Watermark

Watermarks are progress markers left as the result of
interrupted RAID migrations. If the watermark was
cleared, migration should finish.

Array was incomplete due
to missing NV Watermark

RAID migration was interrupted by a shutdown. If
array is online, try migration again. See page 137. If
array is offline, delete and recreate array. See
page 132 and page 131.

Event

Action

Advertising