Chapter 8: Troubleshooting

273

Blowers are NOT installed Reinstall the cooling unit(s). If the blowers does not

turn, replace the blowers. See page 221 or page 226.

Blower status is unknown Check for airflow out of the cooling unit. If there is

none, check for proper installation.

Cache

BBU flushing has started

VTrak’s cache is being flushed.

BBU flushing has ended

VTrak’s cache has been flushed.

BBU flushing has failed

VTrak’s cache could not be flush. Check your cache
flush interval setting. See page 116.

Controller

The controller
parameter(s) changed by
user

The user successfully change controller settings. See
page 116.

The controller has new
crash information

Check the event logs. See page 70.

Controller temperature is
above the threshold/
warning threshold

The VTrak controller is overheating. Check for airflow
around and through the controller, and verify that all
fans are working. Replace fans as needed.

Controller temperature is
above the critical
threshold

The VTrak controller is seriously overheating. Check
for airflow around and through the controller, and
verify that all fans are working. Replace fans as
needed.

Disk Array

New disk array has been
created

Result of settings or user action. Normal.

Disk array has been
deleted

Result of settings or user action. Normal.

Disk array has been
added

Result of settings or user action. Normal.

Disk array has been
removed

The physical drives of the disk array were removed
from the enclosure.

Disk array settings have
been changed

The user successfully logical drive settings. See
page 135.

Drive Interface Controller

Drive-interface controller
found

Normal.

Event

Action