Chapter 8: Troubleshooting

267

Figure 10.A VTrak iSCSI controller

Figure 11. A VTrak SCSI controller

Under normal conditions, the Controller Status LED (marked with

icon) is

green and the Dirty Cache LED (marked with

) icon is dark.

If the Controller Status LED is amber, restart the VTrak. See “Restart the
Subsystem” on page 112
or “Shutdown and Restart” on page 213.

If the Controller Status LED continues to display amber after startup, contact
Promise Technical Support. See “Contact Technical Support” on page 299.

The Dirty Cache LED flashes during input/output operation. If the LED shines
amber and the power is off, there is unsaved data in the cache. Do NOT remove
the cooling unit (M300f/i/p, M200f/i/p) or the cooling unit with the battery
(M500f/i/p) while this LED is on. See “Unsaved Data in the Controller Cache” on
page 295 fo
r more information.

LEDs

State

Dark

Green

Amber

Flashing

Amber

Status no

power

OK

Error

n/a

Dirty Cache

OK

n/a

Unsaved data

in cache

OK

“n/a” means this state does not apply to this LED.

Status LED

Dirty Cache LED

Status LED

Dirty Cache LED