Promise Technology VTrack M-Class M200i User Manual

Page 288

Advertising
background image

VTrak M-Class Product Manual

280

A physical disk has
encountered PFA
condition

A potentially faulty address or bad sector was found.

A configured dead
physical drive has been
inserted

The disk drive inserted into the VTrak was marked as
dead and will not work on the VTrak. Replace the disk
drive.

A physical drive page 0/1
settings have been
changed

Result of settings or user action. Normal.

Physical disk is marked
as dead due to removal/
failure of reassign
sectors/PFA condition/
forced offline state

Replace the disk drive.

PSU (Power Supply Units)

PSU is not inserted/has
been removed

A power supply unit is missing from the VTrak.
Reinstall the power supply unit.

PSU is off

A power supply unit is present but turned off. Turn on
he power supply.

PSU is on

Normal.

PSU is installed/
operational and turned on

Normal.

PSU is installed/
operational and turned off

A power supply unit is present but turned off. Turn on
he power supply.

PSU is malfunctioning
and turned on/off

Replace the power supply unit.

PSU 12V/5V/3.3V power
is out of the threshold
range

Replace the power supply unit.

PSU 12V/5V/3.3V power
is within the range

Normal.

PSU Fans

PSU fan has turned on.

Normal.

PSU fan has turned off.

Verify that the power supply is turned on. If the fan
still does not turn, replace the power supply. See
page 220.

Event

Action