Toshiba Strata DK8 User Manual

Page 105

Advertising
background image

5-35

INSTALLATION-DK 16 KSU & PCB

SECTION 100-816-205

MARCH 1993

16 KCOU REMOVAL AND

REPLACEMENT

16.00 General

16.01 The KCOU comes factory-installed in the
Base Key Service Unit (Figure 5-3); if necessary,
it can be removed and replaced.

16.10 KCOU Removal

1) Make sure the Power Supply (KPSU16) DC

power switch is turned off.

2) Loosen and remove screws 1 and 2 (Figure

5-23).

3) Pull back plastic stand-off tab and pull up on

KCOU until P7 is unplugged.

4) Pull wires on P6 and remove P6 connector

from Base Unit.

16.20 KCOU Replacement

1) Make sure the Power Supply (KPSU16) DC

power switch is off.

2) Mate and connect KCOU P6 cable connector

to P6 on Base Unit motherboard so that the
red wire is aligned as shown in Figure 5-23.

3) Position KCOU as shown in Figure 5-23.

4) Mate and connect KCOU P7 to P7 on the Base

Unit motherboard.

5) Secure plastic stand-off tab and install screws

1 and 2.

6) Set SW400 ~ 475 to appropriate position. In

most cases set to the normal position (NOR);
if CO lines are connected to a PBX or are in
close proximity to the Central Office, set to the
PAD position to provide a 3 db loss in signal
level.

FIGURE 5-23
KCOU PCB

KRCU

BASE UNIT
MOTHERBOARD

SW400

SW425

SW450

SW475

J4 (CO4)

J3 (CO4)

J2 (CO4)

J1 (CO4)

PLASTIC STAND-OFF

(TAB)

SW400 FOR CO1
SW425 FOR CO2
SW450 FOR CO3
SW475 FOR CO4

SCREW (1)

SCREW (2)

P6

RED

RED

P7

KCOU

P2B

P2A

KCOU

SW400

PAD

NOR

Advertising