REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES

SECTION 100-816-600

MARCH 1993

-15-

IMPORTANT NOTE:
For DK16 only: If all programs are initialized, the "IMDU enabled" has also been turned off in
Program 77-1

, LED 14. If using the IMDU for remote programming, go into Program 77-1 and turn

button/LED 14 on as shown in steps 9, 10, and 11. If this is not completed, remote programming
must be reactivated locally from the programming digital or electronic telephone.

TABLE RM-D

PROGRAM 90

INITIALIZING PROGRAMS 00 ~ 97

ACTION

STEP

DISPLAY/PRINTOUT

1

>MODE PROG

Enter the Program Mode
At the >MODE prompt enter

P R O G CR

.

2

P 90

P90

Enter Program Number 90
Press

CR

.

3

P90 00

*

97

To Initialize All Programs Enter

0 0

*

9 7

NOTE: Single programs can be initialized by entering a single
program number plus

#

.

Group numbers are separated by an

*

.

4

P90 00

*

97 01 N

Enter button/LED number

0 1

.

5

P90 00

*

97 01 N Y

Change 01 button/LED to “ON” by entering

Y

.

7

8

Press

CR

.

Press

SPACE

.

6

P90 00

*

97 01 N Y

02 N Y

Initialization complete.

P90 00

*

97 01 N

P90

02 N Y

P90 00

*

97 01 N Y

02 N

9

10

11

12

Exit Program 90
Press

# # CR

.

P90 #

P

For DK16, Enter Program 77
Press

7 7 CR

.

P77

then:

Y CR

.

Press

1 1 4

.

P77 1 14 N

P77 1 14 N Y

P77

To Exit this Program:

Press

# # CR

.

NOTE: If program data is not entered correctly, then

CR

will

not respond. To retry, press

DELETE CR

.

Change LED 02 to “ON” by entering

Y

.