INSTALLATION-PERIPHERALS

SECTION 100-816-207

MARCH 1993

7-9

FIGURE 7-7
DK16 PIOUS RELAY CONTROL FUNCTIONAL WIRING DIAGRAM

ALARM

SENSOR

NORMAL
CLOSE

NORMAL OPEN

ALMT

ALMR

NHR

NHT

DER

DET

BREAK

W1

MAKE

K1

W2

K2

W3

PIOUS

ALM

NH

DE

DOOR

LOCK

CONTROL

MOH

SOURCE

UNIT

FACILITY

ALARM

UNIT

NIGHT BELL

RELAY OPTIONS:

• K1 (DE): DOOR LOCK OR AMP MUTE CONTROL; PROGRAM 77-1, LED 07
• K2 (NH): NIGHT RELAY OR MUSIC-ON-HOLD CONTROL; PROGRAM 77-1, LED 05
• K1 & K2: 24VDC, 1 AMP MAXIMUM

BREAK

MAKE

All wiring connections must be 24 AWG twisted pairs.

TBI

MDF

3.25 Door Lock Assignments Guide

Host

Port
No.

Door
Lock No.

Prog. 39
Assignments

Note: CKT1 must be used in installing DDCB on KCDU
or PDKU. (Must be in Port 12)

DK16 PIOU/PIOUS

Ckt 5 DK16
Base Unit DDCB
Ckt 3 DK8 KSU DDCB

Ckt 1 Expansion Unit
(PDKU or KCDU)
Ckt 4 DK8 KSU DDCB

N/A

04

02

12

03

0

Unlock

Door 0

1

Unlock
Door 1

2

Unlock
Door 2

Code 71

Code 72

Code 73

3.30 DK16 Expansion Unit Night Transfer/
Music-on-Hold Relay Options with PIOU or
PIOUS

3.31 The NHT/NHR relay may be programmed for
either the night relay or the MOH relay function
(refer to Figures 7-6 and 7-7). These functions can
be provided in addition to the relay service provided
by the Base Unit.

3.32 When configured for the night transfer func-
tion with Program 77-1, the relay activates if the
system is in the NIGHT mode. The relay may be