Toshiba Strata DK8 User Manual

Page 155

Advertising
background image

INSTALLATION-PERIPHERALS

SECTION 100-816-207

MARCH 1993

7-23

2) Connect the music source to the music ampli-

fier input.

3) Connect the paging amplifier outputs to PIOU

(PGIN) relays K1 ~ K4 and zone A ~ zone D
speakers (C).

4) Connect the music amplifier (+) output to

terminal 23 (PG COMMON) of the PIOU, and
the (–) output to the “C” terminal of zone A ~
zone D speakers.

5) Connect zone A ~ zone D speakers “A” termi-

nal to the “PGOUT” contact of the PIOU relays
K1~ K4 respectively.

5.16 DK16 Night Ringing over All External Page
Zones (PIOU only).
To allow the night ringing
signal to be sent over zone paging, install the
paging amplifier in accordance with the following
steps (refer to Figure 7-18). (Steps 2 ~ 6 are
performed at the MDF.)

IMPORTANT NOTE: To night ring over
selected PAGE zone, see Paragraph 9 of this
section.

1) Connect the amplifier input via an RJ11 jack to

the J7 600 ohm Page RCA jack on the Base
unit. Or, direct connect J7 to Amp using a
standard audio cable with RCA plugs.

2) Cross-connect the amplifier output A to the

PGIN1 ~ PGIN4 connector from the PIOU.

3) Cross-connect the amplifier output B to the

zone A ~ zone D speaker common line.

4) Cross-connect the PIOU PGOUT1 ~ PGOUT4

to zone A ~ zone D speakers (A).

5) Cross-connect the amplifier output A to pin 9

(NHR) of the PIOU.

6) Cross-connect a jumper from pin 34 (NHT) to

pin 23 (PG COMMON) from the PIOU PCB.

7) In Program 77-1, set LED 05 to OFF and 06

to ON. Set LED 08 to ON if door phones are to
ring over external page when the system is in
NIGHT mode.

8) In Program 78, enable the CO lines that are to

ring via external page when the system is set
in the NIGHT mode.

9) In Program 39, assign the

Night Transfer

1

or

Night Transfer 2

buttons to digital or

electronic telephones per the System Record
Sheets (see Note 2).

10) Press the

Night Transfer 1

or

Night

Transfer 2

button on an electronic or digital

telephone to set the system into the NIGHT
mode. Test by calling into the system on a CO
line assigned (Program 78) to night ring over
external page.

When ringing sounds (see Note 2) over
the page, press

Intercom 5 3 5

to

answer.

NOTES:

1. All zones will ring with this option; night

ringing to selected zones is not possible;
see paragraph 9 for night ring over se-
lected page zones.

2. The

Night Transfer 1

or

Night Trans-

fer 2

buttons put CO lines in NIGHT ring

mode per Program 15; NT1-TENANT 1/
NT2-TENANT 2 CO line assignment.

6 DK8 AND DK16 STATION MESSAGE

DETAIL RECORDING (SMDR) PRINTER/

CALL ACCOUNTING DEVICE OPTIONS

6.00 An SMDR printer or call accounting device
may be connected to the system to provide a hard-
copy record of station activity (incoming, outgoing,
and transferred calls account code entries) on CO
lines or a printout of the customer data base. Call
record data is printed out at the completion of each
call. Program SMDR with Program 60, and use
Program 97 to have the SMDR printer display the
customer data base.

6.01 SMDR will send out special names for the
following types of calls:

MSS: Prints on DISA calls to stations (see Note).

MODM: Prints on calls to the IMDU remote
maintenance modem (station 619).

DISA: Prints on DISA calls to CO lines when

Advertising