FAULT FINDING

SECTION 100-816-500

MARCH 1993

-13-

CHART NO.7

STATION MESSAGE DETAIL RECORDING (SMDR) FAULTS

START

No

SMDR data or

garbled data is

detected at the QSMU,

PIOU/PIOUS SMDR

port.

7-1

Is the

fault

cleared?

YES

7-5

NO

This chart assumes

the SMDR device

has no faults.

NO

END

YES

Read the SMDR

installation

instructions in

paragraph 7 of

Section 100-816-207

before proceeding

with this chart.

SMDR

data records are

sent correctly but not

when the customer

requires.

7-2

YES

Set SMDR options in

Program 60: Threshold

time, long distance

calls only, etc.

Is the

fault

cleared?

YES

7-3

END

7-4

Is the

fault

cleared?

YES

7-6

NO

END

7-7

Check that the SMDR device

is wired correctly to the QSMU,

PIOU/PIOUS SMDR port.

(Refer to PIOU or PIOUS wiring

in Section 100-816-208.)

Fix as required.

Is the

fault

cleared?

YES

7-8

NO

END

Is the

fault

cleared?

YES

7-9

NO

END

Call your technical

support group.

NO

No other faults are

classified. Call your

technical support

group for assistance.

NO

On DK16, the SMDR
port is the bottom
modular jack (TTY is on
top) of PIOU/PIOUS.
On DK8 & DK16, the
modular cord connecting
to the SMDR port must
be 6-wires.

Verify that the SMDR device

communication parameters are

set for: 8-data bits, no-parity,

1-stop bit.

1200 bps on KD8,

300 or 1200 bps on DK16

Change as required.

Change the QSMU,

PIOU or PIOUS PCB.

Call your technical

support group.

On DK8 only, verify that the
QSMU is installed and
programmed for SMDR: Prog.
10-3, LED 04 is off for SMDR.
(QSMU is 1200 bps only)

On DK16 only, Verify that the
PIOU/PIOUS baud rate switch
(SW1) is in the correct position
(300 bps or 1200 bps) to match
the SMDR device baud rate.
(Refer to PIOU/PIOUS
installation instructions in
Section 100-816-205.)

Change as required.