5-36

INSTALLATION-DK 16 KSU & PCB
SECTION 100-816-205
MARCH 1993

FIGURE 5-24
DK16 BASE UNIT POWER FAILURE TRANSFER (PFT) CIRCUIT DIAGRAM

4

3

MOD JACK CO1
(BASE UNIT)

MDF

CO

LINE

5

2

MOD JACK PF1
(BASE UNIT)

R

T

MDF

PFT

STANDARD

TELEPHONE

DK8 OR DK16
KSU MAIN PCB

T

R

POWER FAIL

CONNECTION

POWER AVAILABLE
CONNECTION

KCOU

CO LINE 1

17 DK16 POWER FAILURE EMERGENCY

TRANSFER OPTION

17.00 A dedicated standard telephone can be con-
nected to the Power Failure Transfer Interface
(PF1) on the DK16 Base Unit to provide power
failure backup. During normal operation, this tele-
phone cannot be used—it does not count as a
station; so it does not reduce the system's 20
maximum station capacity. But if there is a power
failure, the telephone will automatically be con-
nected to CO line 1. When power is restored, the
system will automatically resume with its normal
station and CO line assignments, and the dedi-
cated telephone will become inoperative again.

17.10 DK16 Power Failure Emergency Transfer
Installation.
Install the dedicated emergency stan-
dard telephone as follows (see Figure 5-24):

1) Connect a standard telephone to the PF1

connector in the Base Unit.

17.11 DK16 Power Failure Emergency Trans-
fer Test.

1) Turn the system power switch off.

2) Lift the emergency standard telephone hand-

set, and verify that there is CO dial tone.