Toshiba Strata DK8 User Manual

Page 183

Advertising
background image

INSTALLATION-PERIPHERALS

SECTION 100-816-207

MARCH 1993

7-51

10.80 PDIU-DI/PDIU-DS Installation Tests

10.81 Paragraphs 10.82 ~ 10.86 provide tests for
five DIU call applications. The telephone and port
numbers used in these figures are provided for
explanation purposes only; when actually testing,
use port and telephone numbers appropriate for
the system. Each of these tests can be conducted
with manual dialing from a digital telephone’s dial-
pad or AT dialing from a personal computer’s
keyboard; however, only the preferred method of
dialing for application is presented.

10.82 PC-to-PC Test Call Using AT Commands
(see Figure 7-34)

1) DIU Programming:

Program 20: Ports 00 and 01. LEDs 01,
02, and 17 ON; all other LEDs OFF.

Program 39: Ports 00 and 01.

Data

Call

(56) and

Data Release

(54) but-

tons should be provided.

Default settings for PDIU-DI S-Regis-
ters.

2) Make sure PC 1 and PC 2 are on-line with a

communications software package and that
the communication parameters of each PC
and communication software package are set
to the same values (data transmission rate,
parity, data bits, stop bits, flow control, etc.).

3) From PC 1’s keyboard, type

A T D D 1 1

and

press

ENTER

(AT commands must be capi-

tal letters).

The Data Call LEDs will be lit on DKT 10
and 11

PC 1 displays, CONNECT XXXX.

PC 2 displays, RING.

PC 1 and PC 2 are connected as shown
by the thick solid lines. PDIU-DIs are now
in the communication mode.

4) Typing from PC 1 keyboard will display on PC

2 display and vice versa.

5) To terminate the call: Press

Data Release

,

or;

a) Type XXX from either PC keyboard.

The PC screen displays, OK.

FIGURE 7-34
DK8 AND DK16 PC TO PC TEST CALL USING AT COMMANDS

DIGITAL

(PORT 00)

DIGITAL

(PORT 01)

LAPTOP PC 1

RS-232

DKT/PDIU-DI
(10)

MDF

MDF

RS-232

LAPTOP PC 2

DKT/PDIU-DI
(11 )

STRATA DK8 OR DK16