Toshiba Strata DK8 User Manual

Page 165

Advertising
background image

INSTALLATION-PERIPHERALS

SECTION 100-816-207

MARCH 1993

7-33

INSTALLATION-PERIPHERALS
SECTION 100-816-207
MARCH 1993

INSTALLATION-PERIPHERALS

SECTION 100-816-207

MARCH 1993

8.02 Jumper W3 on the PIOUS is used to set the
alarm sensor to detect an open or closed condition
from the facility alarm system. Solder the W3 jumper
wire as follows (refer to Figure 7-23):

To detect a closed condition, solder W3 to the
normal open position.

To detect an open condition, solder W3 to the
normal closed position.

8.03 Alarm Sensor Wiring. Refer to Figure 7-23,
and connect the facility alarm system relay con-
tacts to the PIOU/PIOUS PCB.

9 DK16 NIGHT RINGING

OVER EXTERNAL ZONE PAGE

9.00 In systems shared by two tenants, each tenant’s
CO lines can be assigned to night ring separate
PIOU external page zones (Figure 7-16). This
feature can also be used in one-tenant systems.

9.01 With shared systems, for example, tenant 1’s
night ringing CO lines could be programmed to ring
PIOU external page zones 1 and 2, while tenant 2’s

lines could be programmed to ring zones 3 and 4.
In non-shared systems, night ringing CO lines can
be assigned to ring all of the zones or just selected
zones.

9.02 The following programs must be used to
assign CO lines to ring selected PIOU page zones:

Program 78-1: Assigns CO lines, tenant 1 and
tenant 2, that will night ring over PIOU external
page zones.

Program 15-5: Assigns CO lines to tenant 1 or
tenant 2. Lines are initialized as tenant 1.

Program 77-1 (LEDs 10 ~ 13): Assigns tenant 1
and tenant 2 CO lines to night ring specific PIOU
external page zones. LED 06 must also be ON in
Program 77-1.

Program 39: Assigns appropriate

Night

Transfer

, or

Night Transfer 1 (

tenant 1),

and

NT2

(tenant 2) buttons to electronic and

digital telephones.

NOTES:

1. See Paragraph 5 and Figure 7-16 and

7-17 for PIOU zone paging installation
instructions.

2. Any station can pick up CO lines that night

ring over external page zones by dialing

Intercom 5 9.

FIGURE 7-23
DK16 ALARM SENSOR BLOCK DIAGRAM (PIOU/PIOUS)

PIOU PCB

N.C.

N.O.

P12

ALARM

SENSOR

ALMT (36)

ALMR (11)

25-PAIR CABLE

66 BLOCK PIN NUMBERS

PIOU PIN NUMBERS ( )
25-PAIR CABLE

21

22

FACILITY

ALARM

SYSTEM

MDF

ALARM

SENSOR

NORMAL CLOSE

NORMAL OPEN

ALMT

ALMR

W3

ALM

TB1

TWISTED
PAIR

PIOUS PCB

MDF

FACILITY

ALARM

SYSTEM