FAULT FINDING
SECTION 100-816-500
MARCH 1993

-14-

CHART NO.8

REMOTE MAINTENANCE FAULTS

START

Is Remote

Maintenance connection

via external modem on TTY

port or IMDU

modem?

IMDU modem installed on
PIOU or PIOUS (DK16 only)

8-1

END

Read the Remote Maintenance Section

100-816-600, Paragraphs 1 to 7. This chart

assumes that the remote terminal and

modem have no fault and that Remote

Maintenance does not operate.

Is the

fault

cleared?

Call your technical

support group.

If a Digital or Electronic telephone

is in the programming mode, it is
not possible to enter the Remote

Maintenance mode.

8-5

8-4

Is the

fault

cleared?

8-3

On DK8, check that Prog. 10-3, LED 04 is on

for QSMU TTY operation. Check that the

communication parameters of the remote

terminal are set to match the TTY port (7-data

bits, even-parity, 1-stop bit).

On DK16, check that PIOU/PIOUS SW3

switch

is in the TTY position.

Correct as necessary.

8-2

YES

NO

Check that the modem or terminal connected

to the TTY port is wired correctly per the

Remote Maintenance Section 200-816-600

and QSMU, PIOU/PIOUS MDF wiring in

Section 100-816-208.

Correct above if necessary or

replace QSMU, PIOU or PIOUS.

On DK16, the TTY port is the top
modular jack (SMDR is bottom) of
the PIOU/PIOUS.
On DK8 & DK16 the modular cord
connecting the TTY port to the
terminal or external modem must be
6-wires.

On DK16, check that the IMDU, PIOU, or

PIOUS is installed correctly per Section 100-

816-205.

On DK16, check that the baud rate switch

(SW2, push-button switch on PIOU/PIOUS)

is set to the correct position (300 bps LED

ON, 1200 bps LED OFF) to match the

remote terminal baud rate.

QSMU, TTY Port is 1200 bps only.

Correct as necessary.

External modem
connected to QSMU,
PIOU, PIOUS TTY port

Check that the communication parameters of

the remote terminal are set to match the

IMDU (7-data bits, even parity, 1-stop bit).

Check that the PIOU/PIOUS SW3

switch is in the MODEM position.

Enable the IMDU by turning LED 14 ON in

Program 77-1.
If required, assign CO lines for DISA or to

ring IMDU in system Program 78, Code
51~53.
When calling IMDU via DISA or ring
transfer, dial 619.

Correct above if necessary or

replace IMDU or PIOU(S).