5-21

INSTALLATION-DK 16 KSU & PCB

SECTION 100-816-205

MARCH 1993

FIGURE 5-15
PSTU AND SUBUNIT (SSTU)

TABLE 5-C

PSTU CONTROLS AND INTERFACE CONNECTORS

CONTROL/INDICATOR/

CONNECTOR

(Figure 5-15)

TYPE OF COMPONENT

DESCRIPTION

Ring Voltage W1 Jumper
Plug (PSTU1 ( ) and
PSTU2 only)

Three-terminal jumper

Sets ring generator voltage level for all
circuits.
H = 190V P-P
L = 130V P-P

V.4

BACKPLANE CONNECTOR

50-PIN AMPHENOL CONNECTOR (FEMALE)

SSTU
SUBUNIT

W1

H

L

W1 Ring Voltage
H = 190V P-P
L = 130V P-P
(For PSTU1 (V.4)
and PSTU2 only)

9.13 Unlike the PEKU or PESU, the PSTU does not
have to be configured for BGM: There is no jumper
wire to cut, etc.

9.20 PSTU Installation Procedure

9.21 Install the PSTU in accordance with the fol-
lowing steps:

1) Remove the PCB from its protective packag-

ing. The protective shield on the back of the
PSTU is designed to protect the installer from

NOTE:
PSTU1 (V.4) became available in November
1989. PSTU1(V.3) was discontinued.

9.12 Set the PSTU1 (V.4) or PSTU2 ring generator
level as required:

W1 set to H (190V P-P).

W1 set to L (130V P-P).

Two ringers maximum per port (H or L).