Toshiba Strata DK8 User Manual

Page 90

Advertising
background image

5-20

INSTALLATION-DK 16 KSU & PCB
SECTION 100-816-205
MARCH 1993

Specify code 24 to indicate a PEKU configured
for OCA and an HDSS console.

Program 10-2

Used for BGM connection.

Program 10-3

Used for external amplifier connection.

Program 19

Also used for BGM connection.

Programs 28 and 29

Used for HDSS assignments.

9 STANDARD TELEPHONE

INTERFACE UNIT (PSTU)

9.00 General

9.01 The Standard Telephone Interface Unit
(PSTU) provides an interface between standard
telephones or two-wire devices and the system,
and it must be installed in the Expansion Unit. The
PSTU PCB adds eight standard telephone lines to
the system. The PSTU can also support a Back-
ground Music (BGM) source.

NOTE:
For the system to recognize the Dual-Tone
Multi-Frequency (DTMF) tones generated by
a standard telephone (or any other device
connected to a PSTU port), a DTMF Receiver
Unit (K4RCU) must be installed in the Base
Unit.

9.02 PSTU controls are shown in Figure 5-15 and
described in Table 5-C.

9.10 PSTU (1 and 2) Hardware Options

9.11 There are two PSTU versions (1 and 2): They
are identical except for the ring generator. The ring
generator on the original version (V.3) of PSTU1 is
fixed at a 190V P-P level, while the ring generator
on PSTU1 (V.4) and PSTU2 can be set for 130V P-
P or 190V P-P. The W1 jumper plug is used to set
the voltage level. Most standard telephones and
two-wire devices require the 190V P-P level; how-
ever, some devices may experience ring-trip with
190V P-P and they require the 130V P-P level.

2) Ensure the PEKU has been configured for the

appropriate hardware options (refer to Para-
graph 8.10).

3) Insert the PEKU into the appropriate slot (refer

to Paragraph 5.22), and apply firm, even pres-
sure to ensure proper mating of connectors.

4) After installing the PEKU, gently pull the PCB

outward. If the connectors are properly mated,
a slight resistance will be felt.

8.30 PEKU Wiring

8.31 Refer to PEKU Wiring Diagrams, Section
100-816-208, for wiring/interconnecting details.

8.40 PEKU Programming Overview

8.41 The following parameters may be specified,
through programming, for the PEKU:

Program 03

Specify code 21 to indicate a station line PEKU.

Specify code 22 to indicate a PEKU configured
for OCA.

Specify code 23 to indicate a PEKU configured
for an HDSS console.

J60

J50

J40

J20

J10

FIGURE 5-14
OFF-HOOK CALL ANNOUNCE UNIT (EOCU)
INTERFACE CONNECTORS

Advertising