REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES

SECTION 100-816-600

MARCH 1993

-53-

TABLE RM-BC

PROGRAM 50-6

LCR DIAL ZERO TIMEOUT

ACTION

STEP

DISPLAY/PRINTOUT

1

>MODE PROG

P

Enter Program Mode
At the >MODE prompt, enter

P R O G CR

.

2

P 50

P50

Enter Program Number 50

3

P50 6 06 10

Press

CR

.

4

P50 6 06 10

P50 ##

P

Exit Program/Store Data
A)
B)

To store data, press

CR

.

To exit this program, press

# # CR

.

Enter the number

6

The system will display the present dial zero timeout.
Refer to the System Record Sheet and change if required.
Example: 10, enter

1 0

.

TABLE RM-BD

PROGRAM 51

LCR AREA CODES

ACTION

STEP

DISPLAY/PRINTOUT

1

>MODE PROG

P

Enter Program Mode
At the >MODE prompt, enter

P R O G CR

.

2

P 51

P51

Enter Program Number 51

3

P51 1

Press

CR

.

6

Exit Program/Store Data
A)
B)

C)

To store data, press

CR

.

Continue returning to step 3 until all data has been
entered for this program.
To exit this program, press

# # CR

.

P51 12

212

or

P51 ##

P

4

Enter

2

,

3

, or

4 SPACE

Refer to the System Record Sheet and enter the required
route plan number (1 ~ 8).
Example: Route plan 1, enter

1

.

P51

P51

2

3

4 SPACE

— To add area codes to table.

— To delete area codes from table.

— to display area codes in table,
continue to press

SPACE

to display more codes.

Press

CR

to exit display.

2, 3 or 4

<— CODES

5

Enter codes or

*

and

press

SPACE

after each code entry.

P51

Plan No.